Description
Specs
60 Hz | SQ225 |
---|---|
BTUs (water temp/ambient air/relative humidity) |
|
80/80/80 | 143,000 |
80/80/63 | 134,000 |
80/50/63 | 90,000 |
Coefficient of Performance (water temp/ambient air/relative humidity) |
|
80/80/80 | 6.5 |
80/80/63 | 6.1 |
80/50/63 | 4.0 |
Refrigerant | R410A |
Electrical | |
Heat or Heat & Cool | H |
kW Input | 6.4 |
Voltage/Hz/Phase
|
A, B, E & G |
Minimum/Maximum Fuse Size | A – 60 B – 50 E – 30 G – 25 |
Minimum Circuit Ampacity | A – 42.1 B – 33.3 E – 18.4 G – 16.2 |
Water Flow *A Heater Bypass Kit is required when flow rates exceed the maximum |
|
Minimum/Maximum (gpm) | 30/70 |
Physical | |
Weight (lbs) | 328 |
Size (lengthxwidthxheight) | 34″ x 34″ x 44″ |
Shipping | |
Weight (lbs) | 390 |
Size (lengthxwidthxheight) | 38″ x 36″ x 49″ |
Features
Features
The only heat pump that allows you to maximize the potential savings of a variable speed pump is an AquaCal®, which utilizes our patented ThermoLink® Heat Exchanger technology with its unique flow characteristics. • Patented hydraulic design adds only 1 PSI at 30 gpm, increasing compatibility with two-speed & variable speed pumps. • Saves money when using a variable speed pump by reducing the RPM needed to achieve the same flow rate. • Save money in a single speed pump application by reducing the run time needed to achieve the same turnover rate of the pool. Corrosion Proof Cabinet • Louvered side panels protect evaporator coil while ensuring efficient air flow • Rust and fade proof • Impact resistant • Built-in drain pan provides condensate management AquaTop • Air Flow Vectoring Top protects internal components from weather and debris while ensuring optimal air flow Microprocessor Controlled with Digital Display • Flip-out control panel is out of sight, protected against sun and weather • Lockable panel provides security from others changing the temperature • Accurate and easy-to-read bright blue display • On-board self diagnostics • Microprocessor controlled defrost cycle ThermoLink® Titanium Heat Exchanger • Patented counter-flow water management system • Patented hydraulic design adds only 1 PSI at 30 gpm, increasing compatibility with two-speed & variable speed pumps • Impervious to chemical corrosion • Durability without sacrificing performance • Lifetime warranty
Additional Feature
IceBreaker® Technology:Heat & Cool Models • Extends swimming season longer than any other heat pump on the market • Continue to heat at freezing temperatures to minimize heat loss • Cool your pool to a refreshing temperature • Set to heat, cool or autotemp
Brochures & Manuals
Installation Manuals |
Operation Manuals |
Brochure 60Hz |
Brochure 60Hz (Spanish) |
Brochure 50Hz |
Brochure 50Hz (Spanish) |
Specs 60Hz
60 Hz | SQ125 | SQ145 | SQ225 | SQ120R | SQ166R |
---|---|---|---|---|---|
BTUs (water temp/ambient air/relative humidity) |
|||||
80/80/80 | 101,000 | 119,000 | 143,000 | 110,000 | 126,000 |
80/80/63 | 95,000 | 112,000 | 134,000 | 103,000 | 120,000 |
80/50/63 | 62,000 | 75,000 | 90,000 | 72,000 | 82,000 |
Coefficient of Performance (water temp/ambient air/relative humidity) |
|||||
80/80/80 | 6.5 | 6.8 | 6.5 | 5.5 | 5.6 |
80/80/63 | 6.1 | 6.4 | 6.1 | 5.3 | 5.3 |
80/50/63 | 4.0 | 4.2 | 4.0 | 4.0 | 4.0 |
Refrigerant | R410A | R410A | R410A | R410A | R410A |
Electrical | |||||
Heat or Heat & Cool | H | H | H | H & C | H & C |
kW Input | 4.6 | 5.1 | 6.4 | 5.9 | 6.6 |
Voltage/Hz/Phase
|
A | A, B & G | A, B, E & G | A & B | A, B, E & G |
Maximum Fuse Size | A – 60 | A – 60 B – 50 G – 20 |
A – 60 B – 50 E – 30 G – 25 |
A – 60 B – 50 |
A – 60 B – 50 E – 30 G – 25 |
Minimum Circuit Ampacity | A – 40.5 | A – 42.1 B – 31.0 G – 14.2 |
A – 42.1 B – 33.3 E – 18.4 G – 16.2 |
A – 38.5 B – 31.0 |
A – 42.1 B – 33.3 E – 18.4 G – 16.2 |
Water Flow
*A Heater Bypass Kit is required when flow rates exceed the maximum |
|||||
Minimum/Maximum (gpm) | 30/70 | 30/70 | 30/70 | 30/70 | 30/70 |
Physical | |||||
Weight (lbs) | 268 | 328 | 328 | 268 | 328 |
Size (lengthxwidthxheight) | 34″ x 34″ x 44″ | 34″ x 34″ x 44″ | 34″ x 34″ x 44″ | 34″ x 34″ x 44″ | 34″ x 34″ x 44″ |
Shipping | |||||
Weight (lbs) | 329 | 390 | 390 | 329 | 390 |
Size Length x Width x Height (in) | 38″ x 36″ x 49″ | 38″ x 36″ x 49″ | 38″ x 36″ x 49″ | 38″ x 36″ x 49″ | 38″ x 36″ x 49″ |
Specs 50Hz
50 Hz | SQ145 | SQ225 | SQ120R | SQ166R |
---|---|---|---|---|
Efficiency | ||||
KW Output | 29.3 | 35.2 | 25.8 | 31.7 |
BTU Output | 100,000 | 120,000 | 88,000 | 108,000 |
Coefficient of Performance (C.O.P) | 6.8 | 6.5 | 5.5 | 5.6 |
KW Input | 4.3 | 5.4 | 4.7 | 5.7 |
Electrical | ||||
Heat or Heat & Cool | H | H | H & C | H & C |
Voltage/Hz/Phase H – 200-240/50/1 D – 380-420/50/3 |
H & D | D | H & D | D |
Minimum Circuit Ampacity | H – 38.9
D – 14.2 |
D – 16.2 | H – 38.9
D – 14.2 |
D – 16.2 |
Maximum Fuse Size | H – 60
D – 20 |
D – 25 | H – 38.9
D – 14.2 |
D – 25 |
Refrigerant | R410A | R410A | R410A | R410A |
Water Flow
A Heater Bypass Kit is required when flow rates exceed the maximum |
||||
Minimum/Maximum (m3/h) | 6.8/15.9 | 6.8/15.9 | 6.8/15.9 | 6.8/15.9 |
Minimum/Maximum (gpm) | 30/70 | 30/70 | 30/70 | 30/70 |
Physical | ||||
Weight (kg) | 149 | 149 | 115 | 149 |
Weight (lb) | 328 | 328 | 253 | 328 |
Length x Width x Height (cm) | 87 x 87 x 112 | 87 x 87 x 112 | 87 x 87 x 112 | 87 x 87 x 112 |
Length x Width x Height (in) | 34″ x 34″ x 44″ | 34″ x 34″ x 44″ | 34″ x 34″ x 44″ | 34″ x 34″ x 44″ |
Shipping | ||||
Weight (kg) | 177 | 177 | 143 | 177 |
Weight (lb) | 390 | 390 | 315 | 390 |
Length x Width x Height (cm) | 97 x 92 x 125 | 97 x 92 x 125 | 97 x 92 x 125 | 97 x 92 x 125 |
Length x Width x Height (in) | 38″ x 36″ x 49″ | 38″ x 36″ x 49″ | 38″ x 36″ x 49″ | 38″ x 36″ x 49″ |
Reviews
There are no reviews yet.